Sign In | Join Free | My portofva.com
China Henan Interbath Cable Co.,Ltd logo
Henan Interbath Cable Co.,Ltd
Henan Huanghe Cables Group (Henan Interbath Cable Co.,Ltd)
Active Member

6 Years

Home > XLPE Electrical Cable >

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor

Henan Interbath Cable Co.,Ltd
Contact Now

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor

Brand Name : Huanghe

Model Number : Armoured XLPE Insulated Cable

Certification : IOS OHSAS CCC IEC

Place of Origin : China

MOQ : 200

Payment Terms : TT/Western Union /LC

Supply Ability : 50000meters per week

Delivery Time : 5-8days

Packaging Details : wooden drum

Conductor : Copper/Aluminum

Insulation : XLPE

Armour : DSTA/SWA/AWA

Sheath : PVC/PE

Voltage : 600V to 35KV

Core : 1-5 Core

Standard : BS/IEC/ASTM/DIN

Contact Now

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor

1. Standard of XLPE Insulated Cable:

According to GB12706(Equal to IEC60502). The cable also could be producted by standard of ASTM,BS,DIN and AS/NZS or other standards as request.

2. Rated Voltage of XLPE Insulated Cable:

0.6/1KV, 3.6/6KV, 6/10KV, 8.7/15KV, 12/20KV, 18/20KV, 21/35KV, 26/35KV

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor

3. Construction of XLPE Insulated Cable:

Conductor: Copper or Aluminum

Insulation: XLPE

Inner sheath: PVC or PE

Armour: Double Steel Tape (DSTA), Galvanized Steel Wire (SWA), Aluminum Wire Armoured (AWA)

Outer Sheath: PVC or PE

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor

4. Characters of XLPE Insulated Cable:

a. Max. Long-time operating temperature of XLPE insulated cable is 90°C.

b. Max. short-circuit temperature is not exceed 250°C in 5 Second.

c. Installing temperature of cable should be not less than 0°C.

d. Unable be laid without the limit of fall with enough mechanical pull. Single core cable can not be laid in iron tube or fixed by circled iron tools around cables.

5. Types of Electrical Cable:

Type Designation
YJV Copper conductor, XLPE insulated, PVC sheathed electrical cable Unarmoured Electrical Cable
YJLV Aluminum conductor, XLPE insulated, PVC sheathed electrical cable
YJY Copper conductor, XLPE insulated, PE sheathed electrical cable
YJLY Aluminum conductor, XLPE insulated,PE sheathed electrical cable
YJV22 Copper conductor, XLPE insulated, steel tape armoured, PVC sheathed electrical cable Armoured Electrical Cable
YJLV22 Aluminum conductor, XLPE insulated, steel tape armoured, PVC sheathed electrical cable
YJV23 Copper conductor, XLPE insulated, steel tape armoured, PE sheathed electrical cable
YJLV23 Aluminum conductor, XLPE insulated, steel tape armoured, PE sheathed electrical cable
YJV32 Copper conductor, XLPE insulated, steel wire armoured, PVC sheathed electrical cable Armoured Electrical Cable
YJLV32 Aluminum conductor, XLPE insulated, steel wire armoured, PVC sheathed electrical cable
YJV33 Copper conductor, XLPE insulated, steel wire armoured, PE sheathed electrical cable
YJLV33 Aluminum conductor, XLPE insulated, steel wire armoured, PE sheathed electrical cable

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor

6. Technical Data of 1 core Electrical Cable:

No. of cores and cross -sec. Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 35 24 12/ 20 5.5 1.8 24.9 860 205 190 0.52
1 x 50 24 12/ 20 5.5 1.8 26.4 1138 245 225 0.39
1 x 70 24 12/ 20 5.5 1.9 28.1 1281 305 275 0.27
1 x 95 24 12/ 20 5.5 1.9 29.9 1570 370 330 0.19
1 x 120 24 12/ 20 5.5 2.0 31.3 1839 430 375 0.15
1 x 150 24 12/ 20 5.5 2.0 33.1 2174 490 425 0.12
1 x 185 24 12/ 20 5.5 2.1 34.7 2540 560 480 0.10
1 x 240 24 12/ 20 5.5 2.2 37.1 3120 665 555 0.08
1 x 300 24 12/ 20 5.5 2.2 39.5 3746 765 630 0.06
1 x 400 24 12/ 20 5.5 2.3 44.1 4863 890 725 0.05
1 x 500 24 12/ 20 5.5 2.4 47.6 5905 1030 825 0.04
1 x 630 24 12/ 20 5.5 2.5 51.3 7220 1190 940 0.03

7. Technical Data of 3 cores Electrical Cable:

No.cores

x

cross-sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30℃

Current ratings buried 20℃

maximum DC resistance at 20℃

mm² kV kV mm mm mm kg / km A A Ω/km
3 x 35 24 12/20 5.5 2.6 52.5 3023 155 185 0.52
3 x 50 24 12/20 5.5 2.7 55.5 3891 180 218 0.39
3 x 70 24 12/20 5.5 2.8 59.3 4396 223 267 0.27
3 x 95 24 12/20 5.5 3.0 63 5264 271 318 0.19
3 x 120 24 12/20 5.5 3.1 66.2 6190 312 363 0.15
3 x 150 24 12/20 5.5 3.2 69.8 7240 363 417 0.12
3 x 185 24 12/20 5.5 3.3 73.7 8499 404 460 0.1
3 x 240 24 12/20 5.5 3.5 78.6 10353 471 531 0.08
3 x 300 24 12/20 5.5 3.6 83.8 12328 536 596 0.06
3 x 400 24 12/20 5.5 3.8 93.6 15921 630 684 0.05


Product Tags:

xlpe insulated cable

      

xlpe power cable

      
China DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor wholesale

DSTA SWA AWA XLPE Insulated Cable 1 To 5 Cores Copper Aluminum Conductor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Interbath Cable Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)